Build capability with BEMCON professional training, auditing and consulting. ENQUIRE NOW

Training, Qualifications & Personnel Certification Preparation

Phased Array Ultrasonic Testing (PAUT)

Develop the skills to develop and assess a phased array scan for a defined component. Explore array principles, focal laws and calibration through practical casework. Prepare a phased array scan plan and analysis exercise for review and workplace application.

7 specialist capabilitiesStructured preparation and learningDefined success criteria
Phased Array Ultrasonic Testing (PAUT)
Phased Array Ultrasonic Testing (PAUT)Preparation aligned with the selected training, qualification or certification route

BUILT AROUND YOUR REQUIREMENT

Phased Array Ultrasonic Testing (PAUT) with a clear purpose

Each engagement starts with the required outcome, operating context and evidence of success. The result is a focused Phased Array Ultrasonic Testing (PAUT) scope with clear responsibilities and handover points.

Professional development

Practical training aligned with workplace application and measurable outcomes.

Qualification pathways

Structured preparation for formal learning and assessment routes.

Certification preparation

Focused readiness support for auditor and personnel certification requirements.

Workplace application

Practical outputs that connect learning with operational priorities.

7 SPECIALIST CAPABILITIES

What the service can cover

Select the capabilities that match your Phased Array Ultrasonic Testing (PAUT) requirement, operating context and agreed delivery stage.

01

Duration

5 days / 35 hours

02

Programme route

Personnel certification preparation

03

Learning outcome

Develop and assess a phased array scan for a defined component.

04

Learning outcome

Apply course methods to a case involving focal laws and calibration.

05

Learning outcome

Prepare a phased array scan plan and analysis exercise using a relevant work scenario.

06

Learning outcome

Explain the evidence and limitations behind decisions on indication evaluation.

07

Applied output

A phased array scan plan and analysis exercise.

PROGRAMME PROFILE

Learning, assessment and application

Review the proposed route, learning content, audience and assessment considerations before confirming delivery.

Programme referenceBEM-30-016
Programme routePersonnel certification preparation
Duration5 days / 35 hours
StatusDraft — delivery approval required

Key topics and modules

  • Array principles
  • Focal laws
  • Calibration
  • Scan plans
  • Indication evaluation
  • Case exercise: applying focal laws
  • Case exercise: decisions and limits in scan plans
  • Evidence review: checking indication evaluation
  • Practical workshop: developing the phased array scan plan and analysis exercise
  • Application assessment: develop and assess a phased array scan for a defined component

Who it is for

  • NDT technicians
  • NDT inspectors
  • Inspection engineers
  • Quality control inspectors
  • Method-level certification candidates

Relevant industries

Oil and gas, Power generation, Manufacturing, Construction, Marine engineering

Workplace value

  • Provide teams with a phased array scan plan and analysis exercise to support consistent decisions and clearer handovers.
  • Strengthen review of scan plans and indication evaluation using the course exercises and documented findings.
  • Support performance follow-up through a defined measure: scan coverage demonstrated before examination.

Assessment and entry considerations

Entry and recognition: Preparation only. Select the method, level, industrial sector and certification route before booking. Required training, documented experience, vision eligibility, examinations and employer authorisation must be checked separately; these proposed hours are not asserted to satisfy a certification scheme. The proposed timetable is preparation support, not a declaration that all certification training or experience requirements are met.

Duration basis: Proposed BEMCON taught duration; not an official qualification requirement

HOW WE WORK

From readiness review to confident application

A defined workflow keeps the work aligned with the approved scope and makes progress, decisions and handover easier to manage.

Scope your requirement
  1. 01

    Clarify the requirement

    Confirm the purpose, operating context, stakeholders and expected outcome for Phased Array Ultrasonic Testing (PAUT).

  2. 02

    Agree the delivery plan

    Define activities, responsibilities, inputs, dependencies, checks and approval points.

  3. 03

    Deliver and coordinate

    Complete the specialist work while keeping progress, risks and decisions visible.

  4. 04

    Review and hand over

    Confirm the completed scope, record outcomes and agree practical next actions.

WHAT YOU RECEIVE

Practical outputs and readiness evidence

Confirmed scope

Documented objectives, responsibilities, constraints, assumptions and acceptance points.

Specialist work package

Relevant analysis, coordination and technical work for Phased Array Ultrasonic Testing (PAUT).

Clear evidence and records

Findings, decisions, completed checks and limitations recorded for the agreed scope.

Practical next steps

Prioritised actions for implementation, follow-up, improvement or ongoing support.

LET'S TALK

Request a call back

Tell us what you need and a BEMCON adviser will contact you.